JavaScript Disabled

This site requires JavaScript Enabled to function properly. Please enable JavaScript or use a different browser that has JavaScript enabled.

LG tender box Skip to main content
Log In   |   Register    Brisbane, Queensland

Display Tender GRC008740 
This page displays the details of a tender. See the detailed help in each section for specific information.

206-19 Design & Construct Yarwun Waste Water Treatment Plant Upgrade
Issued By Gladstone Regional Council
Request for Tender
Tender State
Open
Tender Code
GRC008740
Contract Number
206-19
Opening Date
13 April 2019 06:00 AM
Closing Date
21 May 2019 02:00 PM
Category
Nonresidential building construction services - (25%)
Waste water and sewage treatment plant construction service - (50%)
Wastewater engineering - (25%)
Region(s)
South East Queensland
Darling Downs
South West Queensland
Wide Bay North Burnett
Central Queensland
North Queensland
Far North Queensland
Western Queensland
Aboriginal and Torres Strait Islander Councils
Central Australia - Alice Springs
Darwin
Arnhem Land
Katherine
Barkly - Tennant Creek
Tasmania

Contacts 

Contacts

Description 

The Yarwun Wastewater Treatment Plant (YWWTP) is located at 87 Reid Road, Yarwun, about 9 km north-west of Gladstone CBD.  Yarwun WWTP receives flows generated from nearby industrial facilities that are domestic in nature. Although the plant does not treat industrial wastewater and no septage or other tankered wastes are received at the Yarwun WWTP, the composition of the raw wastewater treated at the WWTP has carbon to nutrient ratios that are less than typically expected in domestic wastewater. 

An assessment of the current plant has identified a need for upgrade and refurbishment and GRC requires suitably qualified Contractors to complete the design and construction works for that upgrade and refurbishment. 

The works to be performed under this Contract comprise the design, provision of all materials, plant, labour and the performance of all operations of whatever kind necessary required to upgrade the secondary treatment process through a new package plant, expand the irrigation scheme, and refurbish, (and where necessary) replace equipment to be retained in the waste water treatment process train. 

Specification Documents 

You must be logged in to download documents.
  • 206-19 Invitation to Tender (ITT)  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.1 Principal's Project Requirements - Yarwun WWTP Upgrade  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.1 Appendix A - Yarwun WWTP Condition Assessment  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.1 Appendix B - Soil Investigation Report  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.1 Appendix C - Yarwun WWTP – Asbestos Survey Report 2015  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.1 Appendix D - GRC Water&Sewerage Base Asset Hierarchy Descriptions, As  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.1 Appendix E - Yarwun STP MEDLI Field Assessment (SESL 2017) report  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.2 CMDG DRAWINGS & SPECIFICATIONS REFERENCE LINK  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.3 GRC-ES001_r2 - Electrical Work  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.4 GRC-ES002_r2 - Preferred Electrical Components  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.5 GRC-ES003_r2 - Prefabricated Electrical Switchrooms  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.6 GRC-ES004_r2 - Motor Control Centres  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.7 GRC-ES005_r2 - Lighting & Power Distribution Board  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.8 GRC-ES006_r1 - Field Control Panels  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.9 GRC-ES007_r1 - Control Systems  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.10 GRC-ES008_r2 - Equipment Identification  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.11 GRC-ES009_r0 - Prefabricated Communications Hut Specification  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.12 GRC-ES010_r0 - Communication Power Systems Specification  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.13 GRC-ES013 Fabricated Metalwork Rev 1  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.14 GRC-ES015 - Standard Construction Requirements  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.15 GC-ES016 Standard Construction Requirements for Sewer Pump Stations  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.16 GRC-ES017 _r1 - Polyethylene Pipe Welding Specifications Rev 1  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.17 GRC-ES018 - Standard Requirements Corrosion Protecion of SPS Manholes  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.18 GRC-ES019 Electrical Generator Specification Rev 1  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.19 3.1.1 DRAWING INDEX & LOCALITY PLAN - 83504439-01-001-G001  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.20 3.1.2 OVERALL SITE - IRRIGATION LAYOUT PLAN - 83504439-01-001-C001  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.21 3.1.3 PLANT LAYOUT_INDICATIVE PACKAGE PLANT - 83504439-01-001-C002  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.22 3.1.4 OVERALL SITE _TREE REMOVAL - 83504439-01-001-C003  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.23 3.1.5 P&ID STANDARD SYMBOLS - 83504439-01-001-P001  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.24 3.1.6 P&ID ABBREVIATION FOR NEW EQUIP - 83504439-01-001-P002  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.25 3.1.7 P&ID PRELIM TREATMENT - 83504439-01-001-P003  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.26 3.1.8 P&ID EXIST CLARIFIERS & RAS PUMPS - 83504439-01-001-P004  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.27 3.1.9 P&ID SODIUM HYPOCHLOR DOSING SYSTEM - 83504439-01-001-P005  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.28 3.1.10 P&ID PROPOSED PACKAGE PLANT - 83504439-01-001-P006  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.29 3.1.11 P&ID TYP IRRIGATION SYSTEM - 83504439-01-001-P007  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.30 3.1.12 PROCESS FLOW DIAGRAM -YARWUN WWTP  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.31 Existing Plant DWG files  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.32 Existing Plant control building sewerage scheme  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.33 ExistOperational Manual Volume 1 Yarwun WWTP - Ludowici Environmental  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.34 Existing Plant sewerage treatment plant  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.35 Existing Plant Yarwun STP IO & Tag List  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.36 Environmental Authority  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 2.37 Notice  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 3.1 - Formal Instrument of Agreement, Part A & E  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 4.1 Schedule of Rates - Yarwun WWTP upgrade  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 4.2 Returnable Schedule - Refurbishment  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 4.3 Returnable Schedule - Package Plant  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 4.4 Returnable Schedule - New Pump  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 4.5 Returnable Schedule - Blowers  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 4.6 Returnable Schedule - Mixers  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 4.7 Returnable Schedule - Valve list  
    • Version 1 (12/04/2019)
    • Available by Download
  • 206-19 Attachment 4.8 Returnable Schedule - Instrument list  
    • Version 1 (12/04/2019)
    • Available by Download

Responses 

You must be logged in to submit a response.
Tender closes at 21 May 2019 02:00 PM
Click here to submit an electronic response

Briefings 

Mandatory Briefing & Site Inspection
A briefing session will be held at GRC Calliope Administration Centre, 5 Don Cameron Drive, Calliope, QLD, Australia, 4680 on 30 April 2019 10:00 AM.
Full PPE required
Attendance at the briefing is a pre-requisite to submission and consideration of a bid.

A site visit is a pre-requisite to submission and consideration of a bid.

Online Tender Forum 

Forum posts cannot be posted after 21 May 2019 02:00 PM

The online forum provides a place to comment and obtain further clarification if needed.
In order to submit or comment on a post you must be logged-in and have downloaded the documents.
Comments cannot be posted after 21 May 2019 02:00 PM.

  Link To Forum

Please note that the use of the forum for supplier self-promotion is unacceptable and may result in the supplier having their account suspended. Such posts shall not be responded to or published on the forum.



We reserve the right to invite Tenderers to change their tenders as per Section 228(7) of the Local Government Regulation 2012